Performance Air conditioner on retrofitted refrigerant hydrocarbon

Muhammad Edi Pujianto, Agung Nugroho

Abstract


Synthetic refrigerants used in air conditioner (AC) are very important in depleting the ozone layer and prohibiting global warming. This has led to the application of R32 and Musicool 22 (MC22) as a substitute for R22 because refrigerant is considered more environmentally friendly. Therefore, this research aimed to compare the performance of applying both R32 and MC22 refrigerants in 1 PK split AC using the coefficient of performance (COP) as the indicator for AC performance and compressor power consumption. MC22 filling mass was varied at 90% (202.14 grams), 100% (224.6 grams), and 110% (247.6 grams) of R32 mass, and condenser inlet temperatures at 28°C, 30°C, 32°C, and 34°C. The results showed that MC22 could be used as a viable alternative to R32 due to the higher refrigeration effect value of 332.36 kJ/kg recorded for refrigerant

Keywords


R32, MC22, Power Consumption, Refrigeration Effect

Full Text:

PDF

References


N. Hanifah, I. Wayan Sugita, dan R. Sukarno, “Optimasi sistem pendingin untuk instalasi penyimpanan sementara bahan bakar nuklir bekas di BATAN Optimization Of Cooling System for the Interim Storage for Spent Nuclear Fuel at BATAN,†J. Polimesin, vol. 19, no. 1, hal. 61–68, 2021.

S. H. Pradana dkk., “Studi perhitungan sistem pengkondisian udara dari desain kantor pabrik kelapa sawit berbasis cooling load temperature difference Calculation of cooling energy requirement in the palm oil mill work space based on cooling load temperature difference,†J. Polimesin, vol. 19, hal. 133–139, 2021, [Daring]. Tersedia pada: http://e-jurnal.pnl.ac.id/polimesin/article/view/2093.

K. Sumeru, C. Sunardi, dan M. F. Sukri, "Effect of compressor discharge cooling using condensate on the performance of residential air conditioning system,"AIP Conf. Proc., 2018, doi: 10.1063/1.5049962.

Sariyusda, “Analisa Bentuk Strip Proses Perpindahan Panas Pada Heat Exchanger Pendingin Udara,†Polimesin, vol. 7, no. 2, hal. 685–695, 2009.

T. Priangkoso, N. E. Santoso, T. Apriyanto, dan M. Dzulfikar, “Pengaruh Jenis Refrigerant Dan Diameter Pipa Kapiler Terhadap Kinerja Ac Split,†J. Ilm. Momentum, vol. 14, no. 2, hal. 39–45, 2018, doi: 10.36499/jim.v14i2.2513.

S. Devotta, A. S. Padalkar, dan N. K. Sane, “Performance assessment of HC-290 as a drop-in substitute to HCFC-22 in a window air conditioner,†Int. J. Refrig., vol. 28, no. 4, hal. 594–604, 2005, doi: 10.1016/j.ijrefrig.2004.09.013.

A. Nugroho, A. Nurkholis, R. A. Maulana, dan T. Priangkoso, “The Effect of Retrofitted Refrigerant and Environmental Temperature on the Performance of Air Conditioner: An Experimental Study,†IOP Conf. Ser. Earth Environ. Sci., vol. 997, no. 1, hal. 012007, Feb 2022, doi: 10.1088/1755-1315/997/1/012007.

N. Al Huda dan U. Prayogi, “Alternatif Refrigeran Pengganti R22 Untuk Pendingin Ruangan Berdasarkan Keramahan Lingkungan,†Hexag. J. Tek. dan Sains, vol. 3, no. 1, hal. 40–45, 2022, doi: 10.36761/hexagon.v3i1.1349.

A. Syuhada dan S. Edhy, “Jurnal Polimesin,†vol. 21, no. 1, hal. 131–133, 2023.

A. Amrullah, Z. Djafar, dan W. H. Piarah, “Performance Analysis of Household Refrigeration Machines With Refrigerant Variations,†JTT (Jurnal Teknol. Ter., vol. 3, no. 2, hal. 7–11, 2017.

P. Saksono dan Gunawan, “Penggunaan Refrigeran Hidrokarbon ( HCR ) Sebagai Refrigeran Alternatif,†Semin. Nas. Inov. dan Apl. Teknol. di Ind., hal. 321–326, 2019.

M. M. Dwinanto, W. Bunganaen, dan ..., “Studi Kinerja Teoritis Dan Konsumsi Energi Pengkondisian Udara Menggunakan R22 Dan R290,†LONTAR J. Tek. …, vol. 08, no. 01, hal. 91–98, 2021, [Daring]. Tersedia pada: http://ejurnal.undana.ac.id/index.php/LJTMU/article/view/4966%0Ahttp://ejurnal.undana.ac.id/index.php/LJTMU/article/download/4966/2884.

R. Novrizaldi, “Analisa Pengaruh Jenis Refrigerant Terhadap Unjuk Kerja Mesin Pendingin Ac Split 1 Pk,†Pekan Baru, 2019.

F. A. Pratama, W. H. Mitrakusuma, Muhamad Anda Falahuddin, dan W. S. Ayu, “Kajian kinerja sistem refrigerasi menggunakan refrigeran R32, R22 dan R1270 menggunakan REFPROP,†Pros. 12th Ind. Res. Work. Natl. Semin., hal. 472–477, 2021.

M. Ilham, D. A. Amran, dan A. Irwan, “Analisa Perbandingan Konsumsi Listrik pada AC Split1 PK Menggunakan Freon R32, R410a, dan MC-22,†Simetri Rekayasa, vol. 2, no. 2, hal. 103–115, 2020.

K. Sumeru, T. P. Pramudantoro, dan ..., “Experimental investigation on the performance of residential air conditioning system using water condensate for subcooling,†MATEC Web …, 2018, [Daring]. Tersedia pada: https://www.matec-conferences.org/articles/matecconf/abs/2018/56/matecconf_aasec2018_08002/matecconf_aasec2018_08002.html.

R. I. Tritjahjono, K. Sumeru, A. Setyawan, dan ..., “Evaluation of Subcooling with Liquid-Suction Heat Exchanger on the Performance of Air Conditioning System Using R22/R410A/R290/R32 as Refrigerants,†J. Adv. …, 2019, [Daring]. Tersedia pada: https://akademiabaru.com/submit/index.php/arfmts/article/view/2452.

C. Park, H. Cho, Y. Lee, dan Y. Kim, “Mass flow characteristics and empirical modeling of R22 and R410A flowing through electronic expansion valves,†Int. J. Refrig., 2007, [Daring]. Tersedia pada: https://www.sciencedirect.com/science/article/pii/S0140700707000588.

N. S. Ramu, P. S. kumar, dan M. Mohanraj, “Energy performance assessment of R32/R125/R600a mixtures as possible alternatives to R22 in compression refrigeration systems,†Int. J. Mech. Mechatronics Eng., vol. 14, no. 2, hal. 12–22, 2014.




DOI: http://dx.doi.org/10.30811/jpl.v22i1.3584

Refbacks

  • There are currently no refbacks.




Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

Lisensi Creative Commons

Ciptaan disebarluaskan di bawah Lisensi Creative Commons Atribusi-BerbagiSerupa 4.0 Internasional .

 

Alamat Surat :

Politeknik Negeri Lhokseumawe
Jl. Banda Aceh-Medan Km 280
Buketrata, Lhokseumawe, 24301, Aceh, Indonesia