Abstract
Indonesia is located in the ring of fire and at the convergence of three tectonic plates, making it highly prone to earthquakes. This study aims to evaluate the seismic performance of the Presisi 3 Building at the Indonesian National Police Headquarters and determine its performance level based on displacement. The analysis was carried out using the response spectrum, equivalent static, and pushover methods with ETABS 18.1. The results indicate variations in maximum displacement and drift across the three methods. The pushover analysis produced a performance point with a base shear of 56,270.2575 kN and displacement of 461.685 mm in the x-direction, as well as a base shear of 49,926.4545 kN and displacement of 565.955 mm in the y-direction. According to ATC-40 and FEMA-440, the building’s performance level is categorized as Immediate Occupancy (IO), indicating that the structure remains safe and functional after an earthquake.
Keywords: Displacement, Equivalent Static, Inter-story Drift, Pushover, Response Spectrum.
Keywords
Full Text:
PDF (Bahasa Indonesia)References
Amajida, A. F. (2023). Analisis Kinerja Struktur Apartemen Puncak Kartajaya Surabaya dengan Pembebanan Gempa Dinamik.
Aulia, S. (2021). Analisis Kinerja Struktur Beton Tahan Gempa Dengan Metode Respons Spektrum dan Time History (Studi Kasus: Cisauk Apartment Anami 1.
Cindy, N. K. (2024). ANALISIS KINERJA SEISMIK STRUKTUR BETON DENGAN METODE PUSHOVER (STUDI KASUS: PROYEK GEDUNG 1 ITB INNOVATION PARK (IIP) BANDUNG TEKNOPOLIS PARK (SBSN ITB)).
Dahal, N., Adhikari, B., Thapa, D., Devkota, D., & Arayal, S. (2025). Seismic Performance Assessment of RC Buildings with Variable Soft Storey Configurations and Infill Masonry Using Nonlinear Pushover Analysis. Journal of Civil and Construction Engineering, Vol 11, 9-33.
Elnashai, S. A., & Sarno, D. L. (2008). Fundamental of Earthquake Engineering. United Kingdom: A John Wiley & Sons, Ltd.
Federal Emergency Management Agency (FEMA-440). (2005). Improvement of Nonlinear Static Seismic Analysis Procedures. Redwood City, California.
Hutahean, N., Napitupulu, J., & Nduru, S. (2020). Analisis Dinamis Gaya Gempa Pada Bangunan Berdasarkan SNI 03-1726-2012. Jurnal Ilmiah Teknik Sipil Vol 9 No 2, 91-100.
Mardina, M. T. (2023). EVALUASI KINERJA STRUKTUR APARTEMEN PURI PARKVIEW TOWER E JAKARTA BARAT AKIBAT BEBAN GEMPA DENGAN ANALISIS PUSHOVER.
Safitri, R. A., & Rizki, M. F. (2023). Analisis Penentuan Kebutuhan Shear Wall Terhadap Kekakuan Struktur Menggunakan Time History dan Respon Spektrum Pada Gedung Perkuliahan di Tangerang. Jurnal Teknik Vol. 12 No. 01, 48-56.
Setiawan, D. B. (2021). Evaluasi Kinerja Struktur Gedung Pada Kondisi Batas Layan dan Batas Ultimit dengan Analisis Dinamik Metode Respons Spektrum (Studi Kasus: Gedung Fakultas Hukum Universitas Sam Ratulangi.
Siswanto, S., & Prijasambada. (2023). Analisis Kinerja Struktur Gedung Bertingkat Menggunakan Metode Pushover. Jurnal IKRAITH-TEKNOLOGI Vol 7 No 1.
SNI 1726. (2002). Standar Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung.
Trangipani, N. M., Wirawan , I. A., & Wiryadi, I. G. (2022). Analisis Perilaku Struktur Gedung Sekolah Dengan Metode Respon Spektrum Studi Kasus : SMAN 9 Denpasar. Jurnal Ilmiah Teknik UNMAS Vol. 2, No. 1.
Utami, T. P., & Warastuti, N. (2017). ANALISIS KEKUATAN BANGUNAN TERHADAP GAYA GEMPA DENGAN METODE PUSHOVER STUDI KASUS GEDUNG ASRAMA PUSDIKLAT PPATK, DEPOK . Jurnal Infrastruktur, Vol. 3 No. 2 , 99-106.
DOI: http://dx.doi.org/10.30811/portal.v17i2.7741
Refbacks
- There are currently no refbacks.
Copyright (c) 2025 Hilda Febriyani Pratiwi, Istiqomah - -, Ben Novarro Batubara