Computational Analysis Of Pipe Bend Angle Effect On Pressure Drop

Muhammad Khoirul Akbar, Anis Roihatin, Nur Fatowil Aulia

Abstract


The air conditioning system is a significant energy source inskyscrapersfor supplying cool air to all rooms. However, the process has energy losses due to the ducting used. If the problem of energy loss can be solved, the air conditioning system will bring advantages in terms of energy efficiency and financial savings. A pressure drop in air duct pipe installations, such as pipe bends, is one type of energy loss. This research intends to use Computational Fluid Dynamics (CFD) to investigate the effect of pipe bend angles and velocity relationships on pressure drop in air duct pipe installations, which has previously been validated by experimental research with a 0.17% error percentage. This study focuses on square pipe bends with varying 45o, 60o, and 90o bend angles. The research showed that when testing the highest fluid velocity of 19.68 m/s, the highest pressure drop was 275.69 Pa on the pipe bend angle of 90o, while the lowest pressure drop was 256.41 Pa on the pipe bend angle of 45o. When testing the lowest fluid velocity of 9.77 m/s the highest pressure drop was 67.73 Pa on the pipe bending angle of 90owhile the lowest pressure drop was 62.98 Pa on thepipe bending angle of 45o. The simulation results indicate that the larger pipe bend angle result in a higherpressure drop, and vice versa.


Keywords


Pipe bend angle, fluid velocity, pressure drop, Computational Fluid Dynamics (CFD).

Full Text:

PDF

References


T. Ahmad, A. Aibinu, and M. J. Thaheem, “The Effects of High-rise Residential Construction on Sustainability of Housing Systems,” in Procedia Engineering, Elsevier Ltd, 2017, pp. 1695–1704.

Salimi, S., &Hammad, A,.“Critical review and research roadmap of office building energy management based on occupancy monitoring”. Energy and Buildings, vol. 182, pp. 214-241, 2019.

F. Birol, The Future of Cooling Opportunities for energy-efficient air conditioning Together Secure Sustainable.International Energy Agency, 2018.

Nikmah, A., Amalia, R., &Satrio, D.,“Analysis of the Effect of Bend Angle Outlet Main Steam Line on the Steam Flow Characteristic” . In IOP Conference Series: Earth and Environmental Science, Vol. 972, No. 1, p. 012064). IOP Publishing.

Gajbhiye, B. D., Kulkarni, H. A., Tiwari, S. S., &Mathpati, C. S.,“Teaching turbulent flow through pipe fittings using computational fluid dynamics approach”, Engineering Reports, vol. 2(1), e12093, 2020.

K. Rup, Ł. Malinowski, and P. Sarna, “Measurement of flow rate in square-sectioned Duct Bend,” Journal Of Theoretical And Applied Mechanics, vol. 49, pp. 301–311, 2011.

P. Dutta and N. Nandi, “Effect of Reynolds number and curvature ratio on single phase turbulent flow in pipe bends,” Mechanics and Mechanical Engineering, vol. 19, no. 1, pp. 5–16, 2015.

R. N. Faila and Sutardi, “StudiNumerikKarakteristikAliranFluidaMelalui Rectangular Elbow 90 derajatdengan Diamond Inlet Disturbance Body,” InstitutTeknologiSepuluhNopember, Surabaya, 2018.

R. Nanda Parely and A. FirdausSudarma, “Pengaruh Guide Vanes TerhadapAliranUdarapadaSalurandenganVariasiKecepatanAliranMenggunakanAnsys Fluent,” JurnalSaindanTeknik, vol. 5, no. 1, Jan. 2023.

I. W. Yudhatama and M. I. Hidayat, “Simulasi Computational Fluid Dynamics (CFD) ErosiPartikelPasirdalamAliranFluida Gas Turbulenpada Elbow PipaVertikal - Horizontal,” JurnalTeknik ITS, vol. 7, no. 2, pp. 134–139, 2018.

M. I. FadhilHendrawan, D. Danardono, and S. Hadi, “Studisimulasipenggunaan airfoil naca 6412 sebagaisudupadaturbinangincrossflowmelaluipemodelan CFD 2 dimensi,” JurnalTeknikMesin Indonesia, vol. 13, no. 1, pp. 28–31, 2018.

Nurnawaty and Sumardi, “AnalisisPerubahanTinggiTekananAkibatSudutBelokan 90 derajatdan 45 derajatdenganMenggunakan Fluid Friction Apparatus,” JurnalTeknikHidro, vol. 13, no. 1, pp. 28–37, 2020.

Du, X., Wei, A., Fang, Y., Yang, Z., Wei, D., Lin, C. H., & Jin, Z. “The effect of bend angle on pressure drop and flow behavior in a corrugated duct.”ActaMechanica, vol. 231(9), pp.3755-3777, 2020

M. Saifuddin and P. H. Adiwibowo, “EksperimentalKarakteristik Pressure Drop PadaSambungan T (Tee) Contraction UntukPosisiSearahDenganVariasiSudutKemiringan,” JTM, vol. 1, pp. 74–82, 2013.

I. Eka Putra, S. Sulaiman, and A. Galsha, “AnalisaRugiAliran (Head Losses) padaBelokanPipa PVC,” in PerananIpteksMenujuIndustriMasaDepan (PIMIMD-4), ITP Press, Jul. 2017, pp. 34–39.




DOI: http://dx.doi.org/10.30811/jpl.v22i1.4229

Refbacks

  • There are currently no refbacks.




Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

 

  

    

    

Lisensi Creative Commons

Ciptaan disebarluaskan di bawah Lisensi Creative Commons Atribusi-BerbagiSerupa 4.0 Internasional.

 

Mailing Address:

Politeknik Negeri Lhokseumawe

Jl. Banda Aceh-Medan
Km. 280,3, Buketrata, Mesjid Punteut, Blang Mangat,
Kota Lhokseumawe, 24301

Propinsi Aceh,
Indonesia