THERMAL LOSSES EVALUATION IN 660 MW COAL-FIRED POWER PLANT USING INDIRECT EFFICIENCY METHOD
Sari
Boilers are one of the main equipment in the PLTU apart from turbines and generators. Each year there must be a difference in the actual boiler efficiency value with the conditions during commissioning. Periodically, boiler performance evaluations are carried out in order to identify losses from several factors. In this study, the method used for evaluation is the energy balance method. During the experiment, the standard test guide (ASME PTC - 4) was used. The boiler under test has a capacity of 660 MW. Evaluation is done by comparing the boiler efficiency value at the time of commissioning with the latest performance tests. From the results of performance testing, it is known that the decrease in boiler efficiency when compared with the commissioning results from 86.92% to 82.625%. The reduction in boiler efficiency is due to an increase in heat loss due to dry gas, hydrogen content in coal, and incomplete combustion.
Keywords: boiler, efficiency, evaluation, reduction, performanceTeks Lengkap:
PDFReferensi
Aravind, R. A. et al. (2020) ‘Performance assessment of 2*90 tph (AFBC) boiler and study of HP heater’, Materials Today: Proceedings, 37(Part 2), pp. 404–408. doi: 10.1016/j.matpr.2020.05.389.
Behbahaninia, A., Ramezani, S. and Lotfi Hejrandoost, M. (2017) ‘A loss method for exergy auditing of steam boilers’, Energy, 140, pp. 253–260. doi: 10.1016/j.energy.2017.08.090.
Chao, L. et al. (2017) ‘The Effect Analysis of Thermal Efficiency and Optimal Design for Boiler System’, Energy Procedia, 105, pp. 3045–3050. doi: 10.1016/j.egypro.2017.03.629.
Chen, B. et al. (2021) ‘Investigations on the energy efficiency limits for industrial boiler operation and technical requirements—taking China’s Hunan province as an example’, Energy, 220, p. 119672. doi: 10.1016/j.energy.2020.119672.
Codes, P. T. (2008) ‘Not for Resale Performance Test Codes’, 2008.
Erbas, O. (2021) ‘Case Studies in Thermal Engineering Investigation of factors affecting thermal performance in a coal - fired boiler and determination of thermal losses by energy balance method’, Case Studies in Thermal Engineering, 26(February), p. 101047. doi: 10.1016/j.csite.2021.101047.
Ghalandari, V., Majd, M. M. and Golestanian, A. (2019) ‘Energy audit for pyro-processing unit of a new generation cement plant and feasibility study for recovering waste heat: A case study’, Energy, 173, pp. 833–843. doi: 10.1016/j.energy.2019.02.102.
Lu, J. et al. (2010) ‘Calculation and analysis of dissipation heat loss in large-scale circulating fluidized bed boilers’, Applied Thermal Engineering, 30(13), pp. 1839–1844. doi: 10.1016/j.applthermaleng.2010.04.020.
Nuraini, A. A., Salmi, S. and Aziz, H. A. (2020) ‘Efficiency and Boiler Parameters Effects in Sub-critical Boiler with Different Types of Sub-bituminous Coal’, Iranian Journal of Science and Technology - Transactions of Mechanical Engineering, 44(1), pp. 247–256. doi: 10.1007/s40997-018-0249-7.
Tirumala Srinivas, G. (2017) ‘Efficiency of a Coal Fired Boiler in a Typical Thermal Power Plant’, American Journal of Mechanical and Industrial Engineering, 2(1), p. 32. doi: 10.11648/j.ajmie.20170201.15.
DOI: http://dx.doi.org/10.30811/jstr.v19i01.2263
Refbacks
- Saat ini tidak ada refbacks.
Jurnal Sains dan Teknologi Reaksi is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License
© 2016 All rights reserved |Jurnal Sains dan Teknologi Reaksi p-ISSN: 1693-248X , e-ISSN: 2549-1202.