Inspection of Pipe Welds Using the Radiogrphy Method with the Double Wall Double Image Technique

Aulia Riska, Syukran Syukran, Hasrin Lubis

Abstract


Inspection of 900 angle pipe welds using the Radiography method with an Ir.192 source with a capacity of 150 Curie while operating 56 curies using the Double Wall Double Image Technique Case study at (PT. Sinar Mas, Riau). Errors and inaccuracies in timing result in the resulting image being damaged, not meeting radiographic film acceptance quality standards. irradiation (exposure time). The purpose of this paper is to be able to calculate the exposure time using computation, and to know the type of defects in the welding and there are significant undercutting defects that require repair or re-welding and are declared rejected by the radiographer. The results of the exposure time calculation between the calculations of several processes have a relatively large time difference, this is because they do not follow the curve value. In the end it can be concluded from the results of the film is very influential on the exposure time. Based on this, the resulting software can be declared in accordance with field conditions


Keywords


Air Dryer, Teknik Double Wall Double Image, Camera Gamma Sumber Radiasi Ir-192, Undercutting

Full Text:

PDF

References


ASME 2007 SECTION V, Article 2.

API 1104. Jenis-jenis Cacat lasan,Radiografi dengan film.

AWS D1.1 2002. Kualitas Gambar Radiografi.

BATAN. 2004. Teknik Penyinaran Ellips.

Bagioyono.2002. Hal yang harus di pehartikan dalam inspeksi pipa,Jakarta.

Gilang. 2002. RumusPerhitunganPenyinaran Teknik Ellips. Jakarta.

Irfandi Zulfi. 2014. Developping. Radiography Testing. Batam.

Irfandi Zulfi. 2014. Drying ( Pengeringan Film ). Radiography Testing. Batam.

Irfandi Zulfi. 2014. Fixing. Radiography Testing. Radiography Testing. Batam.

Irfandi Zulfi. 2014. Metode Pengujian Radiographic Testing. Radiography Testing. Batam.

IrfandiZulfi. 2014. Stop Bath. Radiography Testing. Batam.

RADIOGRAFI LEVEL 1 – Teknik Radiografi. 2008. Jakarta.

Sri Widharto.2004 Radiografi Sinar Gamma. Jakarta.




DOI: http://dx.doi.org/10.30811/jowt.v4i2.2992

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

    

   

 

 Lisensi Creative Commons

Ciptaan disebarluaskan di bawah Lisensi Creative Commons Atribusi-BerbagiSerupa 4.0 Internasional.


Mailing Address:

Politeknik Negeri Lhokseumawe

Jl. Banda Aceh-Medan
Km. 280,3, Buketrata, Mesjid Punteut, Blang Mangat,
Kota Lhokseumawe, 24301

Propinsi Aceh,
Indonesia